Advances in Material Chemistry
Vol.04 No.04(2016), Article ID:18740,7 pages
10.12677/AMC.2016.44007

An Efficient and Sensitive Sensor of Phosphorescence Quantum Dots for Determining Hg2+

Ji Chang, Hairong Zhang*

Institute of Biochemical Analysis Technology, Xinzhou Teachers University, Xinzhou Shanxi

Received: Sep. 26th, 2016; accepted: Oct. 12th, 2016; published: Oct. 18th, 2016

Copyright © 2016 by authors and Hans Publishers Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY).

http://creativecommons.org/licenses/by/4.0/

ABSTRACT

The novel Mn-doped ZnS quantum dots of phosphorescence were synthesized in aqueous solution with D-phenylalanine as a stabilizer, which was characterized by fluorescence spectrometry and SEM, respectively. Effects of various factors including the concentration, temperature and pH of quantum dots on sensor were discussed. The results showed that the concentration of Hg2+ in the range of 1.0 × 10−5 mol/L to 8.0 × 10−7 mol/L had good linear relationship, a new method of the determination Hg2+ the sensor had good recognition ability for Hg2+, the detection limit was 2.6 × 10−8 mol/L, and the relative standard deviation was 3.30%. The method can be used to determine Hg2+ in pond water.

Keywords:Mn Doping ZnS Quantum Dots, Room Temperature Phosphorescence, Hg2+, Quenching

一种高效、灵敏测定汞离子磷光量子点传感器

常吉,张海容*

忻州师范学院生化分析技术研究所,山西 忻州

收稿日期:2016年9月26日;录用日期:2016年10月12日;发布日期:2016年10月18日

摘 要

以D-苯丙氨酸为稳定剂,合成具有室温磷光(RTP)的水溶性的Mn掺杂ZnS量子点。利用荧光分光光度计,扫描电子显微镜对合成的锰掺杂硫化锌量子点进行了表征。详细讨论了Hg2+浓度、酸碱度、温度等因素对传感器的影响。结果表明Hg2+的浓度在:1.0 × 105 mol/L~8.0 × 107 mol/L时呈现良好的线性关系,以此建立了测定Hg2+的新方法,该传感器对Hg2+显示出较好的识别能力,检出限为:2.6 × 108 mol/L相对标准偏差为3.30%。该法用于测定池塘水中Hg2+浓度可以得到较为满意的结果。

关键词 :Mn掺杂ZnS量子点,室温磷光,Hg2+,猝灭

1. 引言

量子点是一种新型的半导体纳米材料,自1994年,R.N.Bhargava等人首次报道出锰掺杂硫化锌量子点的合成及相关研究后,锰掺杂硫化锌量子点引起了人们的关注 [1] 。量子点被广泛的应用于光学传感 [2] ,金属离子传感 [3] ,生物传感 [4] 等方面。锰掺杂硫化锌量子点具有罕见的磷光性质,可以将其作为探针检测铅离子 [5] 、镉离子 [6] 、铜离子 [7] ,目前用D-苯丙氨酸作稳定剂的磷光化学传感器测定湖水中的汞离子鲜见报道。

汞是一种化学性质稳定且具有挥发性的剧毒重金属,汞中毒防治已成为世界各国面临的重要课题。目前汞离子的流行检测方法主要包括冷原子吸收法 [8] 原子荧光光谱法 [9] ,原子吸收光谱法 [10] ,电感耦合等离子体质谱法 [11] ,存在仪器昂贵、灵敏度不高、检测成本相对较高等缺点。磷光是受激分子由激发三线态跃迁回到基态而产生的光辐射现象。相对于荧光量子点来说,磷光有较大的Stooks位移,在进行磷光检测时可以避免样品基体荧光和散射光的干扰,选择性大大提高。

本文尝试以D-苯丙氨酸为稳定剂,合成具有室温磷光的水溶性的Mn掺杂ZnS量子点,磷光信号稳定,用于汞离子测定样品不需要分离,该方法亦无需加入除氧剂和诱导剂,方法简便、快速、灵敏,在环境样品、食品、医药等领域金属汞离子的测定有重要的应用价值。

2. 实验部分

2.1. 主要仪器与试剂

pHS-3B型酸度计(上海雷磁仪器厂);KQ-4600KDE型高功率数控超声波清洗器(昆山市超声仪器有限公司);VEGA-3SBH型扫描电子显微镜能谱分析仪(捷克公司);F-4600型荧光光度计(日本日立公司)。

HgCl2 (北京化工厂);1.0 mol/L的NaOH (分析纯,天津市风船化学试剂科技有限公司);MnCl2 (分析纯,天津市风船化学试剂科技有限公司);Na2S (分析纯,天津市风船化学试剂科技有限公司);ZnSO4 (分析纯,天津市风船化学试剂科技有限公司);D-苯丙氨酸(国药集团化学试剂有限公司);其他试剂均为分析纯,实验用水均为二次蒸馏水。

2.2. Mn掺杂ZnS量子点的制备

(稳定剂:D-苯丙氨酸)

2.3. 实验方法

在10 ml比色管中,依次加入3.0 mL pH 11.0的磷酸盐缓冲溶液 [12] ,2.0 mL 8.0 × 10−4 mol/L的HgCl2溶液,以二次蒸馏水定容至10 mL,摇匀。超声10 min,功率为40%。在荧光光度计上记录磷光发射光谱和激发光谱(激发狭缝/发射狭缝:10 nm/20 nm,扫描速度:240 nm/min)。将样品滴于导电硅片上,自然晾干,置于扫描电镜下观察。

3. 结果与结论

3.1. Mn掺杂ZnS量子点的形貌表征

图2可见,所得量子点基本呈球形量子点,又可称为纳米晶 [5] ,是一种由II-VI族或III-V族元素组成的纳米颗粒。

3.2. Mn掺杂ZnS量子点的RTP光谱

在不除氧的条件下,对制备Mn掺杂ZnS量子点的室温磷光性质进行了研究如图3所示,激发波长为272 nm时,Mn掺杂ZnS量子点在600 nm处具有较强的磷光发射。

3.3. Hg2+浓度对Mn掺杂ZnS量子点RTP的影响

图4可看出,随着Hg2+浓度的增加,Mn掺杂ZnS量子点的磷光光谱峰及最大发射峰的位置没有发生变化,但是磷光强度随之减弱。因此可以利用Hg2+对Mn掺杂ZnS量子点室温磷光的猝灭效应可以定量测定Hg2+的含量。

3.4. pH对ΔP的影响

体系考察了pH值对体系磷光强度的影响,ΔP被用于指示猝灭的程度(ΔP = P0 − P1),从图5中可看出,当pH从2.12到8.13的范围内,ΔP的变化不大,在pH = 10时ΔP最大,随后又呈减小的趋势。在制备量子点时我们选用pH = 11.5的磷酸缓冲溶液,所以猝灭实验中选用pH = 10的磷酸缓冲溶液。

在碱性条件下,表面稳定剂量子点表面与D-苯丙氨酸发生了去质子化作用,使量子点与表面稳定剂间共价键强度增加,消除了量子点表面缺陷,导致量子点磷光强度增加。Hg2+能够有效的猝灭量子点的磷光强度是因为生成量子点表面金属氢化物沉淀 [7] 。

Figure 1. The structure of water soluble quantum dots

图1. 制备水溶性量子点结构式

Figure 2. Electron microscopy picture of quantum dots

图2. 量子点的电镜图

Figure 3. The phosphorescence excitation and emission spectra of Mn doping ZnS quantum dots

图3. Mn掺杂ZnS量子点的磷光的激发光谱和发射光谱

3.5. 其它金属离子对Hg2+测定的影响

为了评价Mn掺杂ZnS量子点对Hg2+检测的选择性,在几种常见金属离子存在的条件下Mn掺杂ZnS量子点磷光强度的影响被测定。如图6所示。金属离子的浓度控制在2.0 μM时,将不同的干扰离子加入

(从a到f加入Hg2+浓度(mol/L) 0,5.0 × 10–7,1.0 × 10–6,5.0 × 10–6,1.0 × 10–5,5.0 × 10–5的时所测得的磷光光谱)

Figure 4. Effects of different concentrations of Hg2+ on phosphorescence quantum dots

图4. 不同浓度的Hg2+对量子点磷光的影响

Figure 5. Effects of pH on quantum dots phosphorescence quenching

图5. pH对ZnS量子点猝灭的影响

到浓度为10 µM中的量子点体系溶液中Ag+对量子点有很强的猝灭效应,其他离子对该种方法检测Hg2+的干扰作用小,在含有Ag+的量子点体系中加入过量的Cl-,可消除Ag+的干扰作用,Cl对量子点没有影响。镉离子的浓度低时对磷光的猝灭影响较大,高浓度时影响小 [13] 。在实际样品中,其它干扰离子的含量一般远远低于最大允许存在量,不影响Hg2+的测定。

3.6. 准曲线的建立

以不同浓度的Hg2+对Mn掺杂ZnS量子点溶液的室温磷光影响,测得在最大激发和发射波长处的ΔP,

在此波长下绘制标准液浓度与lgΔP的标准曲线(见图7),计算得:相关系数R2 = 0.9941线性方程为:lgΔP = 0.0819C + 2.6443检出限为:2.6 × 10−8 mol/L(3σ/K)线性范围为:1.0 × 10−5 mol/L~8 × 10−7 mol/L,相对标准偏差3.30%。

3.7. 传感器稳定性检测

在浓度为1.6 × 10−5 mol/L的量子点中加入1.0 × 10−6 mol/L的Hg2+,分别在时间(min):0,20,40,60,100,180,240,360,720,1440检测Hg2+对Mn掺杂ZnS量子点室温磷光强度的影响,ΔP的大小基本不变。以D-苯丙氨酸为稳定剂制作的Mn掺杂ZnS量子点信号稳定,足以完成实际样品测定。

Figure 6. The interference of the metal ions

图6. 其它离子对ZnS量子点猝灭的影响

Figure 7. The standard curve of Mn doped ZnS quantum dots phosphorescence quenching

图7. Mn掺杂ZnS量子点磷光猝灭的标准曲线

Table 1. The determination results of Hg2+ in the sample content

表1. 样品中Hg2 +含量的测定结果

4. 实际样品的测定及回收实验

在样品的检测中为了避免Ag+、Pb2+、Cu2+、Br的影响,加入适量的Cl,以及对Ag+、Pb2+、Cu2+、Br-合适的掩蔽剂 [13] 。取适量处理后的样品至Mn掺杂ZnS量子点溶液中,其它均按最佳实验条件进行,测定该体系的磷光强度,结果见表1

5. 结论

用新的稳定剂D-苯丙氨酸合成一种锰掺杂硫化锌量子点,有很好的水溶性,在1.0 × 10−5 mol/L~8.0 × 10−7 mol/L范围内磷光信号与金属离子汞呈线性关系,最低检出限为2.6 × 10−8 mol/L,经实际样品公园及池塘水中汞离子分析,有较高的灵敏度,锰掺杂硫化锌量子点提供了荧光检测汞离子一种新方法。

基金项目

山西省自然科学基金(No. 2011011007-1);忻州师范学院大学生科技创新项目(院政字2015-88);忻州师范学院重点学科建设项目资助计划(xk201402);忻州师范学院应用化学创新实践基地(2013-31)。

文章引用

常 吉,张海容. 一种高效、灵敏测定汞离子磷光量子点传感器
An Efficient and Sensitive Sensor of Phosphorescence Quantum Dots for Determining Hg2+[J]. 材料化学前沿, 2016, 04(04): 57-63. http://dx.doi.org/10.12677/AMC.2016.44007

参考文献 (References)

  1. 1. Bhargava, R.N., Gallagher, D., Hong, X., et al. (1994) Optical Properties of Manganese-Doped Nanocrystals of ZnS. Physical Review Letters, 72, 416-419. http://dx.doi.org/10.1103/PhysRevLett.72.416

  2. 2. 来守军. 量子点光学传感器的研究进展[J]. 材料导报, 2008, 22(9): 8-10, 25.

  3. 3. 段玉娇, 李文婷, 申前进, 晋卫军. ZnS掺Mn磷光量子点对金属离子传感机理的探讨[J]. 化学传感器, 2011, 31(2): 26-32.

  4. 4. 张璐. 基于磷光量子点Mn-ZnS能量转移体系的生物传感[D]: [硕士学位论文]. 芜湖: 安徽师范大学, 2014

  5. 5. 陈娟, 孙洁芳, 郭磊, 谢剑炜, 孙国祥. 锰掺杂硫化锌量子点室温磷光检测铅离子[J]. 分析化学, 2012, 40(11): 1680-1685.

  6. 6. 赵磊, 苗艳明, 李瑜婷, 连林旺, 闫桂琴. 锰掺杂硫化锌量子点室温磷光检测镉离子[J]. 湖北农业科学, 2015, 54(16): 4033-4037.

  7. 7. 卞伟. 锰掺杂硫化锌量子点磷光探针研究及分析应用[D]: [博士学位论文]. 太原: 山西大学, 2015.

  8. 8. 高木兰, 卞兰柱. 冷原子吸收法测汞应注意的几个问题[J]. 河北化工, 1994(4): 51-53.

  9. 9. 黄志勇, 黄智陶, 张强, 庄峙厦. 原子荧光光谱法测定环境水及土壤样品中的汞形态含量[J]. 光谱学与光谱分析, 2007, 27(11): 2361-2366.

  10. 10. 朱睿. 原子吸收光谱法在测定水中重金属的应用[J]. 污染防治技术, 2013, 26(4): 66-70.

  11. 11. 刘丽萍, 张妮娜, 周珊, 田佩瑶, 毛红. 电感耦合等离子体质谱法(ICP-MS)测定饮用水及水源水中31种元素[J]. 中国卫生检验杂志, 2005, 15(8): 932-934.

  12. 12. 张海容, 王雅乐, 陈金娥. 胶束增敏荧光光度法测定不同蔬菜中草萘胺含量[J]. 分析科学学报, 2012, 28(6): 827-830.

  13. 13. 刘澄. ZnS:Mn量子点的合成及室温磷光检测[D]: [硕士学位论文]. 保定: 河北大学, 2014: 34.