ABSTRACT

This paper designed a set of ion exchange experiment pilot device (1 zeolite + 4 resin) base on the research and experiment. The device’s ability to treat simulate non-radioactive wastewater (including strontium, cesium and cobalt) is verified, and the experimental results show that decontamination factor of ion exchange device was 104 to process strontium, cesium and cobalt.

Keywords:Radioactive Liquid Waste, Ion Exchange, Decontamination Factor

离子交换处理放射性废水的实验研究

杨彬,马若霞,许国静,徐杨华

国家电投集团远达环保工程有限公司重庆科技分公司,重庆

收稿日期:2017年8月21日;录用日期:2017年9月4日;发布日期:2017年9月11日

摘 要

本文在前期调研和实验基础上,设计了一套离子交换中试实验装置(1级沸石 + 4级树脂),并试验了该装置对模拟非放废水(含锶、铯、钴)的处理效果,实验结果表明,该离子交换中试实验装置对锶、铯、钴有较好的去除效果,去污因子达到104

关键词 :放射性废水,离子交换,去污因子

Copyright © 2017 by authors and Hans Publishers Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY).

http://creativecommons.org/licenses/by/4.0/

1. 引言

核电站产生的低水平放射性废水的产量巨大(主要核素包括锶、铯、钴等),必须进行妥善的净化处理,以满足国家越来越严格的排放要求。我国正在运行的核电站基本都是滨海核电站,利用海洋的巨大稀释能力,可将核电站液态流出物对环境的影响尽可能的降低。但对内陆核电项目,由于相对滨海厂址其周边受纳水体的局限性和水环境影响敏感性,对内陆核电的放射性液态流出物的排放提出了更高的要求。因此我国《核电厂放射性液态流出物排放技术要求》(GB 14587-2011)和《核动力厂环境辐射防护规定》(GB 6249-2011)中 [1] ,核电站的放射性液态流出物的排放要求——滨海厂址的核电站,槽式排放出口处的放射性流出物中除H-3和C-14外其他放射性核素浓度不应超过1000 Bq/L,而对于内陆厂址,此数值相应为100 Bq/L (除H-3和C-14外)。要达到此新标准的要求,需要对放射性废水尤其是对内陆核电站所产生废水进行深度处理,放射性废水处理技术要求相应提高。

国内在役核电站的废水处理工艺主要为蒸发和离子交换。蒸发处理对绝大多数废水有良好的适应性,但它能量消耗大、占地大。离子交换技术是非热能处理技术,占空间少,操作灵活,广泛应用于核工业的放射性废水处理中。自我国首座核电厂投入运行以来,离子交换技术在二代加、三代核电(各种堆型)的放射性废水净化处理中都得到了应用 [2] [3] 。

本文通过前期调研和选取离子交换材料的实验结果,选择4A沸石和罗门哈斯树脂作为处理锶、铯、钴的离子交换材料 [4] [5] ,设计了一套离子交换中试试验装置,并试验了该装置对模拟废水(含锶、铯、钴)的处理效果。

2. 模拟废水配置

放射性废水是指核电厂、核燃料循环以及放射性同位素生产、应用过程中产生的带有放射性污染或活化核素的各种废水。不同废水所含放射性核素的种类和活度浓度、酸碱度、常规化学组分等差异很大。核电站的放射性废水中,主要核素包括Co、Cs、Sr等。

本实验用去离子水配制含硝酸锶(Sr(NO3)2)、硝酸铯(CsNO3)、硝酸钴(Co(NO3)2)的模拟废水2 m3,模拟非放废水含有硝酸锶(Sr(NO3)2)、硝酸铯(CsNO3)、硝酸钴(Co(NO3)2)各10 mg/L。每次试验前均取原水样分析检测。

3. 试验装置及方法

离子交换处理流程图如图1所示,主要包括供水单元、离子交换单元、过滤器吸附单元等。供水单元:由废水配水罐、循环水泵、液位计等组成,完成废水配制、原水供料任务。离子交换单元:由进料泵、流量计、压力表、沸石吸附单元(1级4A沸石)、树脂吸附单元(4级罗门哈斯树脂)组成,去除离子态的核素。过滤吸附单元:由1级丝网过滤器组成,用于去除废水中的悬浮物及有机物。

离子交换中试试验装置如图2所示,模拟废水通过进料泵依次经过5台串联的离子交换床单元(1级4A沸石 + 4级罗门哈斯树脂)和过滤器单元,设计处理能力200 L/h。系统稳定运行1小时后,间隔一定时间在每台离子交换柱下游出口取样检测。

4. 试验结果与讨论

离子交换装置处理模拟废水的试验结果如图3~图5所示。

Figure 1. Flow diagram of ion exchange process

图1. 离子交换处理流程图

Figure 2. Pilot test device of ion exchange

图2. 离子交换中试试验装置

(a) (b)

Figure 3. Experimental result of treat Sr using ion exchange device. (a) Decontamination factor of treat Sr by zeolite; (b) decontamination factor of treat Sr by resin

图3. 离子交换装置去除锶试验结果。(a)沸石去除锶DF值;(b)树脂去除锶DF值

(a) (b)

Figure 4. Experimental result of treat Cs using ion exchange device. (a) Decontamination factor of treat Cs by zeolite; (b) decontamination factor of treat Cs by resin

图4. 离子交换装置去除铯试验结果。(a)沸石去除铯DF值;(b)树脂去除铯DF值

(a) (b)

Figure 5. Experimental result of treat Co using ion exchange device. (a) Decontamination factor of treat Co by zeolite; (b) decontamination factor of treat Co by resin

图5. 离子交换装置去除钴试验结果。(a)沸石去除钴DF值;(b)树脂去除钴DF值

图3所示,离子交换装置中4A沸石对锶的DF值约为104,但随着时间增加,4A沸石会慢慢饱和,因此对锶的去除能力会下降。1级树脂对锶的DF值随时间的增加而变大,2~4级树脂的出水浓度小于1 ug/L,均在测量仪器的检测限(1 ug/L)以下。总装置对锶的DF值约为104

图4所示,离子交换装置中4A沸石对铯的DF值约为103,同样随着时间增加,4A沸石会慢慢饱和,因此对铯的去除能力会下降。1级树脂对铯的DF值随时间的增加而变大,2~4级树脂的出水浓度小于1 ug/L,均在测量仪器的检测限(1 ug/L)以下。总装置对铯的DF值约为104

图5所示,离子交换装置中4A沸石对钴的DF值约为5 × 10。1级树脂对钴的DF值约为2 × 102,2~4级树脂的出水浓度小于1 ug/L,均在测量仪器的检测限(1 ug/L)以下。总装置对钴的DF值约为104。在实验过程中去污因子会有波动。

5. 总结

从上述数据分析可以得出,4A沸石对锶的处理效果最好,但随着时间的增加,4A沸石会慢慢饱和,去除效果会变差。该离子交换中试实验装置装载1级4A沸石和1级罗门哈斯树脂即能对锶、铯、钴有较好的去除效果,去污因子达到104。但为了达到更好的处理效果,建议1级沸石后至少加两级罗门哈斯树脂。

后续采用该离子交换装置(装载1级4A沸石和2级罗门哈斯树脂)对100 mg/L的模拟废水进行了处理,总装置对锶、铯、钴的去污因子大于104

基金项目

2015年集团科技项目(2015-188-CQD-KJ-X)。

文章引用

杨彬,马若霞,许国静,徐杨华. 离子交换处理放射性废水的实验研究
Experimental Study on Treating the Radioactive Waste Water by Ion Exchange[J]. 核科学与技术, 2017, 05(04): 211-215. http://dx.doi.org/10.12677/NST.2017.54027

参考文献 (References)

  1. 1. 国家环境保护部. GB6249-2011——核动力厂环境辐射防护规定[M]. 北京: 中国环境科学出版社, 2011.

  2. 2. 柳丹, 刘杰安. 离子交换树脂处理核电厂废液模拟试验研究[J]. 给水排水, 2012(增刊): 248-251.

  3. 3. 李福志, 孙大卫. 内陆AP1000核电项目低放废液排放的主要污染物及其处理技术[J]. 原子能科学技术, 2012, 46(S1): 137-141.

  4. 4. 方祥洪, 马若霞, 杨彬. 放射性废水的离子交换树脂处理性能研究[J]. 广东化工, 2016, 43(24): 122.

  5. 5. 方祥洪, 杨彬, 马若霞. 放射性废水的无机离子吸附处理性能研究[J]. 山东化工, 2017, 46(1): 129-130.